Settings - Switch settings

Switch Settings 1 VXS-AM

DIP switch settings

DIP switch VXS-AM

LED

OFF: LED is not activated except during warm-up and walk test.

ON: LED is activated according to the detector's status.

Alarm

N.C.: Normally closed.

N.O.: Normally open.

AUX input

AND: AND inverter. Both the detection AND AUX input occur within 60 seconds, it activates the alarm.

OR: OR inverter. Either the detection OR AUX input activates the alarm.

Anti-masking

OFF: Anti-masking OFF

ON: Anti-masking ON

When masking condition continues more than 3 minutes, Trouble will be generated. Trouble is generated after 20 seconds under the anti-masking test mode.

Antimasking teaching
DIP switch VXS-DAM

LED

OFF: LED is not activated except during warm-up and walk test.

ON: LED is activated according to the detector's status.

Alarm

N.C.: Normally closed.

N.O.: Normally open.

AUX input

AND: AND inverter. Both the detection AND AUX input occur within 60 seconds, it activates the alarm.

OR: OR inverter. Either the detection OR AUX input activates the alarm.

Anti-masking

OFF: Anti-masking OFF

ON: Anti-masking ON

When masking condition continues more than 3 minutes, Trouble will be generated. Trouble is generated after 20 seconds under the anti-masking test mode.

Antimasking teaching

Microwave immunity

NORM: It is used under normal condition.

IMMUNITY: It is used under harsh environment.

Future use

-------

PIR sensitivity

Switch Settings PIR 1 VXS