Installation - Wiring

Terminals

1_Wiring-1 VXS-ST_hontai2
3_Wiring-1 VXS-AM

Power

9.5 to 18 V DC

Spare

Trouble

N.C. 28 V DC 0.1 A max.

Following condition makes a trouble signal.
[1] Masking detection

Common

Common use between Alarm and Trouble

Alarm

N.C./N.O. selectable by DIP switch No.2, 28 V DC 0.1 A max.

Tamper

N.C. 28 V DC 0.1 A max.

AUX input

AND/OR logic is selectable by DIP switch No.3.

Power cable length

The power cable should be limited to the following length.

Unit: m (ft.)

Wire gauge

VXS-AM
Current draw 24 mA

VXS-DAM
Current draw 35 mA

AWG 22
[ 0.33 mm2 ]

240 (790)

160 (520)

AWG 20
[ 0.52 mm2 ]

380 (1,250)

260 (850)

AWG 18
[ 0.83 mm2 ]

600 (1,970)

410 (1,350)

Unit: m (ft.)

Wire gauge

VXS-AM
Current draw 24 mA

VXS-DAM
Current draw 35 mA

AWG 22
[ 0.33 mm2 ]

520 (1,710)

360 (1,180)

AWG 20
[ 0.52 mm2 ]

820 (2,690)

560 (1,840)

AWG 18
[ 0.83 mm2 ]

1,310 (4,300)

900 (2,950)